Research Article

Application of Improved Phase Lock Method in Weak Signal Extraction

Table 3

Analysis results of signals and .

Test batchSNRSine functionTheoretical valueTest value
AmplitudeFrequencyPhaseAmplitudePhase

Test 1−35Sine function 10.0120 Hz0.6 0.0080.65 pi
Sine function 20.0240 Hz0.8 0.020.8 pi
Sine function 30.0360 Hz0.6 0.030.6 pi

Test 1−45–55Sine function 10.0120 Hz0.6 0.0180.56 pi
Sine function 20.0240 Hz0.8 0.0240.76 pi
Sine function 30.0360 Hz0.6 0.0320.57 pi
Test 1Sine function 10.0120 Hz0.6 0.030.4 pi
Sine function 20.0240 Hz0.8 0.0520.5 pi
Sine function 30.0360 Hz0.6 0.020.4 pi

Test 4−35Triangular wave0.02220 Hz0.0110.5 pi
0.00260 Hz0.000090.5 pi