Research Article

Rapid Identification of Economic Indicators of Integrated Energy Systems Based on Data Analysis

Table 7

Coefficient among different indicators with economy-first solutions.

Coefficient of associationDesign load indicator (W/m2)Initial investment ($/m2)Yearly energy sale (kwh/m2/year)Equivalent full load power hours per year (h)Yearly energy sale proceeds ($/year/m2) ($/m2)Static payback time (year)Initial investment per unit energ一production ($/kWh)

Design load indicator (W/m2)1.00
Initial investment ($/m2)0.921.00
Yearly energy sale (kwh/m2/year)0.460.391.00
Equivalent full load power hours per yea (h)−0.53−0.510.481.00
Yearly energy sale proceeds ($/year/m2) ($/m2)0.190.170.960.691.00
Static payback time (year)0.360.49−0.57−0.86−0.701.00
Initial investment per unit energ一production ($/kWh)0.340.52−0.54−0.83−0.660.981.00