Comparison of individual harmonics as % of the fundamental voltage.

Harmonic orderFundamental RMS output voltage
TheoreticalSimulation

h139.8411(100%)39.98(100%)
h300.15918
h500.035373
h700.035373
h900.141493
h1100.106118
h1300.070745
h1500.053059
h1700.15918
h1995.1367893.95075
h2195.1367894.00383
h2300.141493
h2500.053059