Comparison of SAC and AEM in terms of harmonic distortion factor.

Harmonic orderSACAEM
THDTHD

h396.314640.15918
h591.535940.035373
h784.641220.035373
h975.947860.141493
h1165.808550.106118
h1354.664110.070745
h1542.990670.053059
h1731.246710.15918
h1919.9083293.95075
h219.41633494.00383
h230.10580.141493
h257.7058780.053059