Research Article
The Evaluation of Classifier Performance during Fitting Wrist and Finger Movement Task Based on Forearm HD-sEMG
Table 3
Overall average accuracy (%).
| Channels | LDA | KNN | SVM | Random forest |
| 8 | 99.7 ± 0.029 | 99.4 ± 0.043 | 99.2 ± 0.071 | 93.75 ± 0.11 | 32 | 98.51 ± 0.074 | 97.92 ± 0.083 | 96.73 ± 0.097 | 86.61 ± 0.27 | 64 | 95.83 ± 0.093 | 91.67 ± 0.14 | 86.9 ± 0.24 | 83.3 ± 0.45 |
|
|