Research Article
Error Calibration of Cross Magnetic Gradient Tensor System with Total Least-Squares Method
Table 6
RMS errors of tensor components before and after calibration.
| ā |
|
|
|
|
|
|
|
| Raw data | 3317.25 | 2723.87 | 2936.66 | 8606.44 | 4405.69 | 1752.09 | 7213.74 | Corrected data by the original method | 51.736 | 31.316 | 17.545 | 29.711 | 20.691 | 13.226 | 65.439 | Corrected data by the proposed method | 28.302 | 14.158 | 17.196 | 18.655 | 16.153 | 13.047 | 32.214 |
|
|