Research Article

Optimization of Disk Magnetic Coupler Based on Orthogonal Test and Multiobjective Genetic Algorithm

Table 3

Orthogonal test schemes and test results.

NOABCTmax (N·m)P (W/m3)Comprehensive evaluation value

15530.373.3E − 0740.87
251070.345.5E − 0722.74
351550.556.2E − 0723.37
410570.346.1E − 0718.03
5101050.955.7E − 0738.94
6101531.726.4E − 0755.88
715550.908.4E − 0716.31
8151031.807.2E − 0751.93
9151571.557.4E − 0743.08