Research Article

Numerical Study of Acoustic-Electric Signal Conversion for GIS Discharge Detection and Structure Optimization for pMUT

Table 4

The central displacement amplitude (max) and output voltage amplitude (max) in acoustic-solid-pMUT coupling simulation for different computational grids.

GridsRegionsMinimal grid size (μm)Maximal grid size (μm)Total grid numbersmax × 10−3 (μm)max ()

Grid 1Zone 119.27142.8657483.021.35
Zone 210.01176.77
Zone 37.59124.09

Grid 2Zone 119.25100.00107172.621.74
Zone 210.00118.03
Zone 36.55124.09

Grid 3Zone 118.1176.92177062.711.82
Zone 210.0092.25
Zone 36.25111.62

Grid 4Zone 112.8462.50268042.751.87
Zone 29.8471.99
Zone 35.87100.23

Grid 5Zone 111.1252.63384262.781.88
Zone 29.2661.24
Zone 35.5760.18