Research Article
A Comparative Energetic Analysis of Active and Passive Emission Control Systems Adopting Standard Emission Test Cycles
Table 1
Operative conditions for the working fluid and emission control systems.
| Reference converter size, (height; width; length) | 141 mm | 141 mm | 300 mm | Cell density, | 62 cell/cm2 | Channel size, | 0.90 mm | Wall thickness, | 0.35 mm | Wetted surface per unit volume, | 2201 m−1 | Solid phase density, | 2807 kg/m3 | Solid specific heat capacity, c | 800 J/kg K | Exhaust flow rate, | 100 g/s | Exhaust gas temperature, | 200 (700)°C | Initial solid temperature, | 700 (200)°C | Cycle time, | 20 s |
| Further exhaust flow rate, | 22 ÷ 252 g/s | Further exhaust gas temperature, | 194 ÷ 616°C | Further initial solid temperature, | 194 ÷ 434°C | Further converter length, | 400 ÷ 600 mm | Further cycle time, | 30 ÷ 60 s |
|
|