Research Article

Flexible Temporary Shield in Soft and Sensitive Clay: 3D FE Modelling of Experimental Field Test

Table 9

Soil pressure at different depths of the excavation by the PLAXIS-3D MC model with different .

Depth from top (m)Soil pressure (kPa)
/gravity loading

0000
0.91.51013
2.4263955
3.9445266
5.4607998