Research Article
Progressive Collapse Resistance Mechanism of RC Frame Structure Considering Reinforcement Corrosion
Table 1
Material properties of steel reinforcement.
| Corrosion rate η/% | Diameter of steel bar/mm | Yield strength fy/MPa | Ultimate strength fu/MPa | Elongation δ/% |
| 0 | 6 | 348 | 486 | 25.4 | 12 | 438 | 577 | 16.6 | 16 | 466 | 605 | 16 | 4.8 | 6 | 324 | 453 | | 12 | 408 | 538 | 15.1 | 10 | 6 | 296 | 413 | | 12 | 373 | 490 | 13.15 | 4.2 | 6 | 270 | 376 | | 12 | 340 | 447 | 11.7 | 20 | 6 | 307 | 404 | | 12 | 307 | 403 | 9.7 | 25 | 6 | 218 | 304 | | 12 | 274 | 360 | 7.98 | 28.6 | 6 | 192 | 267 | | 12 | 250 | 329 | 7.1 |
|
|