Research Article

Progressive Collapse Resistance Mechanism of RC Frame Structure Considering Reinforcement Corrosion

Table 2

Comparative analysis of the FEM and test results.

Test numberYield load Fy (kN)Peak load Fp (kN)Ultimate load Fu (kN)
TESTFEMTESTFEMTESTFEM

BS-05657.677.277.688.589.70.9720.9950.986
BS-15-549.1506361.945.958.90.9821.0180.779
BS-30-542.841.753.154.137.741.61.0230.9820.906
Average value:0.9920.9980.891
Standard deviation:0.040.030.14