Research Article
Assessment of Fractional and Integer Order Models of Induction Motor Using MATLAB/Simulink
Table 1
Induction motor parameter values.
| Quantity (unit) | Symbol | Motor I | Motor II | Motor III |
| Rated power (KW) | | 0.75 | 2.2 | 3 | Stator resistance (ohm) | | 10 | 9.2 | 2.3 | Stator leakage inductance (H) | | 0.4642 | 0.43 | 0.267 | Rotor resistance (ohm) | | 6.3 | 4.1 | 0.55 | Rotor leakage inductance (H) | | 0.4612 | 0.43 | 0.261 | Mutual inductance (H) | | 0.4212 | 0.44 | 0.249 | Frequency (Hz) | | 60 | 60 | 60 | Pole number | | 2 | 4 | 6 | Inertia (Kg.m2) | | 0.02 | 0.042 | 0.0076 | Friction factor (Nm) | | 0.2 | 0.0031 | 0.0007 | Rotor angular velocity(rad/sec.) | | 373.7 | 185.4 | 122.63 |
|
|