Research Article

Early Oxidative Stress Response in Patients with Severe Aortic Stenosis Undergoing Transcatheter and Surgical Aortic Valve Replacement: A Transatlantic Study

Table 4

Changes in oxidative stress-related biomarkers according to transcatheter or surgical aortic valve replacement.

Measured parameter TAVR ()SAVR ()Adjusted value

GSH S10.018
GSH S20.931
GSH S3 (nmol/mg protein)0.498
Slope for trend0.022-0.330
value0.698<0.001
GSSG S10.942
GSSG S20.650
GSSG S3 (nmol/mg protein)0.475
Slope for trend-0.0050.003
value0.8420.804
GSH/GSSG S10.568
GSH/GSSG S20.380
GSH/GSSG S30.237
Slope for trend1.860-0.880
value0.3190.199
FRAP S10.410
FRAP S20.017
FRAP S3 (μmol/L)0.212
Slope for trend12.6-0.22
value0.0270.983
8-Isop S10.553
8-Isop S20.635
8-Isop S3 (pg/mL)0.046
Slope for trend-2.5646.5
value0.860.028

GSH = reduced glutathione; GSSG = oxidized glutathione; FRAP = ferric-reducing ability of plasma; S = sample; SAVR = surgical aortic valve replacement; SD = standard deviation; TAVR = transcatheter aortic valve replacement; 8-Isop = 8-isoprostane.