Research Article

Selective Hole Filling of Red Blood Cells for Improved Marker-Controlled Watershed Segmentation

Table 2

Performance evaluation on high number of overlapping cells samples.

MethodTPFPFNAccuracyPrecisionRecallF1

Proposed study793270.9890.9970.9910.994
Classic hole filling replacement7282280.9600.9970.9620.979
-means clustering replacement73315640.9020.9790.9190.948

TP: true positive; FP: false positive; FN: false negative.