Scanning / 2022 / Article / Tab 1 / Research Article
Quantitative Analysis of Cone-Beam Computed Tomography Artifacts Induced by Nonmetallic Root Canal Filling Materials Using Different Fields of View: In Vitro Study Table 1 Paired
-test for pre- and postobturation scans in the coronal and middle thirds.
Section Material FOV Value Mean Std. dev. Std. error 95% confidence interval of the difference df Sig. Lower Upper Coronal third Gutta-percha Min 8.200 28.642 9.057 -12.289 28.689 0.905 9 0.389 Max -2.200 4.211 1.331 -5.212 0.812 -1.652 9 0.133 Skew. -0.774 0.497 0.157 -1.130 -0.418 -4.921 9 0.001 Min -0.300 35.882 11.347 -25.968 25.368 -0.026 9 0.979 Max 3.900 5.384 1.702 0.0484 7.751 2.291 9 0.048 Skew. 1.038 0.582 0.184 0.621 1.454 5.638 9 0.000 Glass-fiber post Min -2.900 32.925 10.412 -26.453 20.653 -0.279 9 0.787 Max -1.800 3.735 1.181 -4.472 0.872 -1.524 9 0.162 Skew. -0.478 0.914 0.289 -1.132 0.175 -1.656 9 0.132 Min 7.100 26.768 8.464 -12.048 26.248 0.839 9 0.423 Max 1.700 1.828 0.578 0.391 3.008 2.940 9 0.016 Skew. 0.406 0.703 0.222 -0.097 0.909 1.825 9 0.101 Middle third Gutta-percha Min 12.800 15.310 4.841 1.847 23.752 2.644 9 0.027 Max -4.400 6.203 1.961 -8.838 0.0380 -2.243 9 0.052 Skew. -0.0743 0.556 0.175 -0.472 0.323 -0.422 9 0.683 Min -19.400 24.495 7.746 -36.923 -1.876 -2.504 9 0.034 Max 2.000 5.477 1.732 -1.918 5.918 1.155 9 0.278 Skew. -0.025 0.633 0.200 -0.478 0.427 -0.126 9 0.903 Glass-fiber post Min -3.500 26.437 8.360 -22.412 15.412 -0.419 9 0.685 Max -2.500 4.453 1.408 -5.685 0.685 -1.775 9 0.110 Skew. 0.040 0.434 0.137 -0.270 0.351 0.295 9 0.775 Min 3.400 22.652 7.163 -12.804 19.604 0.475 9 0.646 Max 4.500 4.904 1.551 0.991 8.008 2.901 9 0.018 Skew. 0.097 0.515 0.163 -0.271 0.466 0.599 9 0.564