Research Article
Nonintrusive Sensor System Developed Using a Force-Sensing Resistor for Pipeline Integrity Monitoring
Table 3
Pressure measured using intrusive and nonintrusive sensors.
| Intrusive sensor (bar) | Nonintrusive sensor (bar) | Gap | % |
| 6.16 | 6.19 | 0.029 | 0.5 | 5.66 | 5.72 | 0.063 | 1.1 | 5.15 | 5.28 | 0.133 | 2.6 | 4.64 | 4.80 | 0.159 | 3.4 | 4.13 | 4.28 | 0.156 | 3.8 | 3.62 | 3.80 | 0.175 | 4.8 | 3.11 | 3.28 | 0.170 | 5.5 | 2.61 | 2.76 | 0.154 | 5.9 | 2.09 | 2.20 | 0.106 | 5.1 | 1.59 | 1.68 | 0.093 | 5.8 | 1.07 | 1.12 | 0.045 | 4.2 | 0.97 | 1.04 | 0.065 | 6.7 | 0.87 | 0.92 | 0.048 | 5.5 | 0.77 | 0.80 | 0.033 | 4.3 | 0.67 | 0.72 | 0.051 | 7.7 | 0.57 | 0.60 | 0.031 | 5.5 | 0.46 | 0.48 | 0.018 | 3.9 | 0.36 | 0.40 | 0.038 | 10.6 | 0.26 | 0.29 | 0.027 | 10.3 | 0.16 | 0.16 | 0.004 | 2.3 | 0.00 | 0.00 | 0.000 | 0.0 |
|
|