Research Article

Real-Time Integration of Identification and Semiactive Optimization Control for Mass Damper-Building Combined Systems under Known/Unknown Seismic Excitations

Table 3

Comparisons of identified damping coefficients (known seismic excitation).

Story noExact (N/m)Identified c (N/m)Error (%)

1st60006062.19−1.04
2nd60006000.280.00
3rd60006155.54−2.59
4th60006162.43−2.71
5th60006247.43−4.12
6th60005546.107.56
7th60005907.441.54
8th60005789.723.50
9th60006159.76−2.66
10th60005962.920.62
SAMD100100.09−0.10