Comparisons of identified damping coefficients (unknown seismic excitation).

Story noExact (N/m)Identified c (N/m)Error (%)

1st60006002.02−0.03
2nd60006130.07−2.17
3rd60006067.38−1.12
4th60005946.770.89
5th60005761.883.97
6th60006001.38−0.02
7th60005889.001.85
8th60005900.951.65
9th60006281.78−4.70
10th60006073.32−1.22
SAMD100100.04−0.05