Journals
Publish with us
Publishing partnerships
About us
Blog
Structural Control and Health Monitoring
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
Structural Control and Health Monitoring
/
2023
/
Article
/
Tab 6
/
Research Article
Real-Time Integration of Identification and Semiactive Optimization Control for Mass Damper-Building Combined Systems under Known/Unknown Seismic Excitations
Table 6
Comparisons of identified damping coefficients (unknown seismic excitation).
Story no
Exact (N/m)
Identified c (N/m)
Error (%)
1st
6000
6002.02
−0.03
2nd
6000
6130.07
−2.17
3rd
6000
6067.38
−1.12
4th
6000
5946.77
0.89
5th
6000
5761.88
3.97
6th
6000
6001.38
−0.02
7th
6000
5889.00
1.85
8th
6000
5900.95
1.65
9th
6000
6281.78
−4.70
10th
6000
6073.32
−1.22
SAMD
100
100.04
−0.05