Research Article

Theoretical and Experimental Analysis of a Winding Rope Fluid Viscous Damper

Table 3

Loading protocol.

SpecimensF0 (kN)u0 (mm)f (Hz)lc

D1N1R14, D2N1R14, D3N1R14210, 20, 50, 700.45
D2N1R14, D2N2R141, 2, 4, 6, 8500.25
D3N1R08, D3N2R081, 2, 4, 6, 8, 10500.25
D3N1R0861000.230