Research Article

Video Motion Magnification and Subpixel Edge Detection-Based Full-Field Dynamic Displacement Measurement

Table 2

ConvLSTM model structure.

ConfigurationModel 1Model 2Model 3

ConvLSTM2DFilters = 32, kernel size = (3, 3)Filters = 32, kernel size = (3, 3)Filters = 32, kernel size = (3, 3)
Batch normalization
ConvLSTM2DFilters = 32, kernel size = (3, 3)Filters = 32, kernel size = (3, 3)
Batch normalization
ConvLSTM2DFilters = 32, kernel size = (3, 3)
Batch normalization
Conv2DFilters = 32, kernel size = (3, 3)Filters = 32, kernel size = (3, 3)Filters = 32, kernel size = (3, 3)
MaxPooling2DPool size = (4, 4)Pool size = (4, 4)Pool size = (4, 4)
Flatten
Dense512512512
Dropout0.50.50.5
Dense512512512
Dense128128128
Dense333