Review Article
Nondestructive Testing and Health Monitoring Techniques for Structural Effective Prestress
Table 1
Research studies on structural prestress monitoring based on FBG sensors.
| Publication year | Researchers | Measuring object | Laboratory or field | Encapsulating and embedding method | Measuring error | Note |
| 1996 | Nellen et al. [45] | Prestressed carbon fiber cable | Laboratory | FBG sensor was fixed on the strand surface using glue and Teflon tape | — | — | 2009 | Zhou et al. [46] | PSC beam | Laboratory | FBG sensor was embedded in an FRP bar | Within 5% | Smart steel strand | 2011 | Li et al. [47] | Stay cable | Laboratory | FBG sensor was embedded in a GFRP bar | With a maximum error of 11.86% | Smart stay cable | 2012 | Li et al. [48] | Arch bridge suspender | Both | FBG sensor was embedded in a GFRP bar | — | Smart suspender | 2012 | Kim et al. [49] | PSC beam | Both | FBG sensor was encapsulated by epoxy resin and steel tube | Within 5% | Smart steel strand | 2013 | He et al. [50] | Bridge cable | Laboratory | FBG sensor was embedded in a FRP bar | Within 5% | Smart cable | 2014 | Lan et al. [51] | PSC beam | Laboratory | FBG sensor was embedded in a FRP bar | Within 5% | Smart steel strand | 2014 | Li and Zhou [52] | Bridge cable | Laboratory | Using adhesive to join FBG sensor and steel wire | Within 4.5% | — | 2015 | Kim et al. [53] | Steel strand | Laboratory | FBG sensor was embedded in a carbon core wire | — | Smart steel strand | 2016 | Kim et al. [44] | Pretensioned UHPC deck | Both | FBG sensor was encapsulated by epoxy resin and steel tube | — | Smart steel strand | 2017 | Huynh and Kim [54] | PSC girder | Laboratory | FBG sensor was embedded in a carbon core wire | — | Smart tendon | 2017 | Kim et al. [55] | Steel strand | Laboratory | FBG sensor was encapsulated by epoxy resin and steel tube | — | Smart steel strand | 2018 | Zheng et al. [56] | Steel wire for bridge cable | Laboratory | Using structural adhesive to join FBG sensor and steel wire | — | — | 2018 | Dan et al. [57] | Steel strand | Laboratory | FBG sensor was embedded in a carbon fiber bar | — | Smart tendon | 2020 | Jiao et al. [58] | Steel strand | Laboratory | FBG sensor was embedded in a FRP bar | Within 7% | Smart steel strand | 2021 | Zhu et al. [40] | PSC beam | Laboratory | FBG sensor was embedded in the groove of the center wire | | Self-sensing steel strand |
|
|