Review Article
Nondestructive Testing and Health Monitoring Techniques for Structural Effective Prestress
Table 2
Research studies on structural prestress monitoring based on ME sensors.
| Publication year | Researchers | Measuring object | Laboratory or field | Measuring error |
| 2005 | Sumitro et al. [65] | PSC tendon, stay cable | Both | Within 10% | 2008 | Tang et al. [66] | Steel cable | Laboratory | — | 2013 | Joh et al. [67] | Prestressed tendon | Laboratory | — | 2014 | Zhang et al. [68] | Steel cable | Laboratory | — | 2014 | Tang et al. [69] | Steel cable | Laboratory | — | 2016 | Cho et al. [70] | PSC steel strands | Laboratory | — | 2016 | Duan et al. [71] | Stay cable | Both | Within 2% | 2017 | Xiu et al. [72] | Steel cable | Laboratory | — | 2018 | Ren et al. [73] | Steel cable | Both | | 2018 | Zhang et al. [74] | Steel cable | Laboratory | — | 2018 | Chen and Zhang [75] | PSC tendon | Laboratory | — | 2018 | Liu et al. [76] | Steel strand | Laboratory | 0–7.7% | 2018 | Feng et al. [77] | Stay cable | Field | — | 2018 | Guo et al. [78] | PSC tendon | Laboratory | — | 2019 | Zhang et al. [64] | Steel cable | Laboratory | — | 2020 | Kim and Park [79] | PSC tendon | Laboratory | — | 2021 | Liu et al. [80] | Steel wire rope | Laboratory | Within 5% | 2021 | Zhang et al. [41] | Steel strand | Laboratory | Within 10% | 2021 | Zhang et al. [81] | Steel strand | Laboratory | 12.5%, 11.9%, and 9.5% |
|
|