Research studies on cable force evaluation based on structural dynamic response.

Publication yearResearchersStructural typeAcquisition method for vibration responseLaboratory or fieldTesting error

2007Kim and Park [87]Stay cableAccelerometerBoth3%
2010Cho et al. [88]Stay cableAccelerometerLaboratoryWithin 10%
2011Choi and Park [89]Stay cableAccelerometerField
2014Yu et al. [90]Stay cableAccelerometerBothWithin 8%
2015Zhao et al. [91]Stay cable and suspenderSmartphone with built-in accelerometerBothWithin 5%
2017Bao et al. [85]CableAccelerometerLaboratoryWithin 5%
2019Rango et al. [92]Stay cableHigh-speed cameraLaboratoryWithin 7%
2019Yan et al. [93]Stay cableVideo cameraLaboratoryWithin 5%
2020Zhao et al. [94]Stay cableMicrowave interferometric radarFieldWithin 2%
2020Kim et al. [95]Hanger cableDigital cameraFieldWithin 2%
2020Du et al. [96]Stay cableDSLR cameraLaboratoryWithin 4%
2020Yan et al. [97]Hanger cableVideo cameraBothWithin 6%
2021Chu et al. [98]Stay cableCameraLaboratoryWithin 5%
2021Jeong et al. [99]Stay cableAccelerometerBothWithin 6%
2021Jana and Nagarajaiah [100]Stay cableHandheld cameraFieldWithin 15%
2021Jo et al. [101]Stay cableDigital cameraField
2021Tian et al. [102]Hanger cableUnmanned aerial vehicleBothWithin 3%
2021Wang et al. [103]Stay cableSmartphoneFieldWithin 2%
2021Yu et al. [104]CableAcoustic radiation methodLaboratoryWithin 2%
2022Zhang et al. [105]Stay cableDroneBoth
2022Jana et al. [106]Stay cableAccelerometerFieldWithin 3%
2022Wangchuk et al. [107]Stay cableVideo cameraBothWithin 8%
2022Jana et al. [108]Stay cableCameraFieldWithin 8%
2023Kim et al. [109]Stay cableCameraFieldWithin 3%
2023Wang et al. [110]Stay cableCamera and unmanned aerial vehicleField