Research Article

Identification Uncertainties of Bending Modes of an Onshore Wind Turbine for Vibration-Based Monitoring

Table 1

Natural frequencies , the damping ratio of the simulation model, and the identification results of BAYOMA or the SSI-COV.

Method in Hz in %
(CoV) (CoV) (CoV) (CoV)

DeSiO0.29730.3021
BAYOMA0.2975 (0.10%)0.3021 (0.20%)0.13 (139.3%)0.35 (61.8%)
SSI-COV0.29740.30170.200.11

The CoV in % is shown in brackets for the BAYOMA identification results (since DeSiO includes only velocity damping but not modal damping, no equivalent damping ratio can be determined, for details, see [34]).