Research Article
Gust Factor Approach for Estimating Maximum Response and Control Force in High-Rise Base-Isolated Buildings with Active Structural Control
Table 1
Parameter of the mathematic model.
| | Parameter | Symbol | Value |
| Superstructure | Height | | 100 m | Width | | 25 m | Depth | | 25 m | DOF | — | 10 | Height of each story | | 10 m | Density | | | 1st natural period | | 2 s | 1st damping ratio | | 0.02 |
| Isolation | Width | | 25 m | Depth | | 25 m | DOF | — | 1 | Mass per unit area | | | Isolated period | | 4 s | Isolated damping ratio | | 0.05 |
|
|