Research Article
Analog Circuit Soft Fault Diagnosis Based on Sparse Random Projections and K-Nearest Neighbor
Table 4
Diagnosis results in the noisy environment.
| Fault code | The proposed method (%) | BayesNet (%) | Decision tree (%) | SVM (%) |
| F1 | 100 | 99.5 | 99.5 | 93 | F2 | 98 | 94 | 92.5 | 80 | F3 | 99 | 90 | 96.5 | 54.5 | F4 | 100 | 96.5 | 95 | 60.5 | F5 | 100 | 93.5 | 96 | 76 | F6 | 100 | 95 | 95 | 78 | F7 | 100 | 100 | 99.5 | 77 | F8 | 100 | 97.5 | 99 | 94 | F9 | 100 | 100 | 94.5 | 97.5 | F10 | 100 | 100 | 99.5 | 92.5 | F11 | 98 | 96 | 93.5 | 57 | F12 | 99.5 | 92.5 | 96 | 65.5 | F13 | 99 | 96 | 95 | 57.5 | Average result | 99.5 | 96.19 | 96.27 | 75.62 |
|
|