Research Article
Study on the Combination of Pump Rod Pipe in Complex Structure
Table 3
Comparison of parameters of three different combinations of pipe combination.
| ā | General pipe rod combination | Lined oil pipe rod and pipe combination | Laser tubing rod and pipe combination |
| Axial force (kN) | 62.7 | 43.23 | 50.4 | Extension (m) | 0.9826 | 0.7034 | 0.7981 | Lateral force (N) | 137.7 | 95.97 | 110.6 | Safety factor | 4.851 | 7.037 | 6.035 |
|
|