Research Article

Nuclear Power Plant Maintenance Optimization with Heuristic Algorithm

Table 2

First ten MCS identified from the FT of the analyzed AFW system.

No.ProbabilityShare (%)Event 1Event 2Event 3

1 23.4AFW-CKV-OO-CV142AFW-TDP-FS-FW2
2 22.3AFW-CCF-FS-FW3ABAFW-TDP-FR-2P6HR
3 13.4AFW-CKV-OO-CV157AFW-MDP-FS-FW3A
4 13.4FW-CKV-OO-CV172AFW-MDP-FS-FW3B
5 8.2AFW-CCF-FS-FW3ABAFW-TDP-FS-FW2
6 7.4AFW-CCF-FS-FW3ABAFW-TDP-MA-FW2
7 2.5AFW-MDP-FS-FW3AAFW-MDP-FS-FW3BAFW-TDP-FR-2P6HR
8 2.1AFW-TNK-VF-CST
9 0.9AFW-MDP-FS-FW3AAFW-MDP-FS-FW3BAFW-TDP-FS-FW2
10 0.8AFW-MDP-FS-FW3AAFW-MDP-FS-FW3BAFW-TDP-MA-FW2

Top event probability