Research Article
The Optimization of Radiation Protection in the Design of the High Temperature Reactor-Pebble-Bed Module
Table 3
The annual work durations and dose rates of RPV, SG, and helium circulator.
| | Work position | Work duration | Dose rate | Collective dose | (man-hours) | (mSv/h) | (man-Sv/a) |
| RPV | 1 | 15 | 3.50 | 199.05 | 2 | 15 | 3.63 | 3 | 30 | 1.78 | 4 | 10 | 3.87 |
| SG
| 1 | 50 | 0.91 | 62.82 | 2 | 50 | 0.23 | 3 | 50 | 3.89 × 10−4 | 4 | 50 | 0.12 |
| Helium circulator | 1 | 20 | 0.95 | 54.02 | 2 | 10 | 1.75 | 3 | 10 | 1.75 |
|
|