Simulation and Analysis of Small Break LOCA for AP1000 Using RELAP5-MV and Its Comparison with NOTRUMP Code

Table 1

AP1000 safety system actuation set point during SBLOCA [5].

System/functionActuation set pointsTime delays (sec)

Reactor trip12.41 MPa2.0
“S” signal generation11.72 MPa2.0
SG feed-water control valves start to closeAfter reactor trip signal3.2
Main steam isolation valves start to closeAfter “S” signal4.8
Reactor coolant pumps tripAfter “S” signal6.0
PRHRS isolation valve starts to openAfter “S” signal0.0
CMT actuationAfter “S” signal0.0
Accumulator actuation4.83 MPa0.0
ADS-1 actuationAfter CMT water volume reduces to 67.5%20.0
ADS-2 actuation70 s after ADS-1 actuation30.0
ADS-3 actuation120 s after ADS-2 actuation30.0
ADS-4A actuation20.0% liquid volume fraction in CMT2.0
ADS-4B actuation60 s after ADS-4A actuation2.0
IRWST injectionPressure < 89.6 kPa + the containment pressure2.0