Research Article

Development and Validation of Rapid 3D Radiation Field Evaluation Technique for Nuclear Power Plants

Table 1

Information of dose rate in the selected typical radiological compartment.

Measurement pointGlobal coordinates relative to the center of the core (cm)Measured dose rate (mSv/h)
xyz12345Average

A276413421321.1230.8550.9170.8640.8660.925
B276413421650.9450.9721.0830.9861.0141.000
C256212961561.2211.0821.0251.2331.0641.125
D258712771281.4251.2591.3151.2251.2761.300
E250612201290.4820.5250.5140.5430.5610.525
F25901150500.1950.1830.1760.1920.1790.185
G26901150500.1120.0890.0950.1060.0880.098
H28601150500.0520.0460.0580.0510.0480.051
I28601340500.0330.0380.0410.0310.0320.035
J28601730500.0050.0090.010.0060.0050.007