Research Article

Monte Carlo Simulation and Experimental Validation for Radiation Protection with Multiple Complex Source Terms and Deep Penetration for a Radioactive Liquid Waste Cementation Facility

Table 3

The indoor measured H∗(10) compared with the FLUKA calculated results.

Distance to the drum (m)H∗(10)/μSv/hF/M value
Measurement valueFLUKA calculation

101190 ± 803120 ± 902.6
50410 ± 30840 ± 302.0
1180 ± 10330 ± 101.8
258 ± 4113 ± 31.9