Calculated thermal-hydraulic parameter on steady-state condition.

Hottest channelCOOLOD-N2EUREKA-2/RRExisting XS MTR-DYNNew XS MTR-DYNFLUENT

Operating power, (MW)30.030.030.030.030.0
Inlet coolant temp, (°C)44.544.544.544.544.5
Max. Coolant temp, (°C)68.6367.92 (1.03%)67.01 (2.36%)66.29 (3.41%)66.82 (2.63%)
Max. Cladding temp., (°C)121.66123.10 (−1.18%)121.44 (0.18%)121.62 (0.03%)121.26 (0.32%)
Max. Fuel temp, (°C)125.11126.02 (−0.73%)122.41 (−2.15%)122.60 (2.01%)123.10 (1.60%)
Saturation temp, (°C)117.32117.39
MDNBR1.621.69