Research Article
Experimental and Numerical Studies of AP1000 Shield Building considering Fluid-Structure Interaction
Table 6
Comparison of acceleration amplification factors.
| PGA (g) | Ground motion | Acceleration amplification factor | Acceleration reduction ratio (%) | Model-I | Model-II |
| 0.10 | Scaled El ground motion | 2.596 | 3.204 | −18.98 | Scaled artificial ground motion | 3.088 | 3.741 | −17.46 |
| 0.15 | Scaled El ground motion | 2.808 | 3.320 | −15.42 | Scaled artificial ground motion | 3.250 | 3.638 | −10.67 |
| 0.20 | Scaled El ground motion | 2.878 | 3.099 | −7.13 | Scaled artificial ground motion | 3.382 | 3.636 | −6.99 |
| 0.30 | Scaled El ground motion | 2.659 | 3.034 | −12.36 | Scaled artificial ground motion | 3.128 | 3.512 | −10.93 |
|
|