Peak strain at the bottom and strain reduction ratio.
| PGA (g) | Ground motion | Peak strain () | Strain reduction ratio (%) | Model I | Model II |
| 0.10 | Scaled El ground motion | 20.71 | 21.67 | −4.43 | Scaled artificial ground motion | 39.19 | 41.26 | −5.02 |
| 0.15 | Scaled El ground motion | 31.61 | 33.31 | −5.10 | Scaled artificial ground motion | 60.35 | 67.64 | −10.78 |
| 0.20 | Scaled El ground motion | 41.33 | 44.86 | −7.87 | Scaled artificial ground motion | 79.23 | 89.44 | −11.42 |
| 0.30 | Scaled El ground motion | 61.28 | 68.23 | −10.19 | Scaled artificial ground motion | 129.94 | 148.09 | −12.26 |
|
|