Research Article

Experimental and Numerical Studies of AP1000 Shield Building considering Fluid-Structure Interaction

Table 8

Peak strain at the bottom and strain reduction ratio.

PGA (g)Ground motionPeak strain ()Strain reduction ratio (%)
Model IModel II

0.10Scaled El ground motion20.7121.67−4.43
Scaled artificial ground motion39.1941.26−5.02

0.15Scaled El ground motion31.6133.31−5.10
Scaled artificial ground motion60.3567.64−10.78

0.20Scaled El ground motion41.3344.86−7.87
Scaled artificial ground motion79.2389.44−11.42

0.30Scaled El ground motion61.2868.23−10.19
Scaled artificial ground motion129.94148.09−12.26