Research Article
Shaking Table Testing of a Scaled Nuclear Power Plant Structure with Base Isolation
Figure 21
Floor response spectrum of the pressure vessel support (A2) (conversion to the prototype). (a) Structure with isolations along the x-direction; (b) structure without isolations along the x-direction; (c) structure with isolations along the y-direction; (d) structure without isolations along the y-direction; (e) structure with isolations along the z-direction; (f) structure without isolations along the z-direction.
(a) |
(b) |
(c) |
(d) |
(e) |
(f) |