Research Article

Time-Series Forecasting of a Typical PWR Undergoing Large Break LOCA

Table 2

Normalized uncertain parameters [28, 30].

Nos.Parameter descriptionMean, μPDFStandard deviation, σRange,

1Core power1.0Normal0.01550.9691–1.0309
2Groeneveld-CHF1.0Normal0.5000.171–2.1711
3Chen nucleate boiling HTC1.0Normal0.2340.382–1.618
4Transition boiling HTC1.0Normal0.2300.54–1.46
5Dittus–Boelter liquid HTC1.0Normal0.1960.607–1.393
6Dittus–Boelter vapor HTC1.0Normal0.1960.607–1.393
7Film boiling HTC1.0Normal0.2870.426–1.574
8Break discharge coefficient1.0Normal0.1150.77–1.23
9Decay heat1.0Normal0.0510.898–1.102
10Oxidization dial1.0Normal0.010.980–1.020
11SIT actuation pressure1.0Normal0.0250.949–1.051
12SIT loss coefficient1.0Normal0.200.6–1.4
13Pressurizer pressure1.0Normal0.1130.77–1.23
14Fuel thermal conductivity1.0Normal0.07730.8455–1.1545
15Gap conductanceUniform0.75–1.50
16Downcomer wall thermal conductivityUniform1.0–2.0
17SIT water inventoryUniform0.9634–1.0372
18Pump two-phase head multiplierUniform0.0–1.0
19Pump two-phase torque multiplierUniform0.0–1.0
20SIT water temperatureUniform0.955–1.045
21SIP (IRWST) water temperatureUniform0.936–1.064
22SIP flow multiplierUniform0.5–1.5
23Pump K-factorUniform0.239–0.577