Research Article

Time-Series Forecasting of a Typical PWR Undergoing Large Break LOCA

Table 5

Transient validation for key events.

Timing of key events (s)ModelDCD

Break occurs00
Reactor trip signal occurs5.86.2
SI injection signal occurs5.86.2
SIT discharge begins16.014.4
SIP initiated48.046.2
SIT empty time204.0201.5