Research Article

Intelligent Diagnosis Method for Centrifugal Pump System Using Vibration Signal and Support Vector Machine

Table 1

DI values and standard deviation of DI values of 3 NSPs between two states from the signals estimated by statistic filter.

Two statesIn mild stepIn medium stepIn severe stepDI’s standard deviation

Normal state and abnormal state0.540.610.730.830.790.921.291.161.310.380.280.30
Cavitation and impeller unbalance0.610.550.800.820.650.881.271.040.940.340.260.07
Cavitation and shaft misalignment0.580.640.720.760.900.871.030.981.260.230.180.28
Impeller unbalance and shaft misalignment0.680.770.790.930.841.031.111.091.170.220.170.19