Research Article
Intelligent Diagnosis Method for Centrifugal Pump System Using Vibration Signal and Support Vector Machine
Table 6
The diagnostic results of various states with the defect degrees by the proposed method.
| Test state | Defect degree | Simple diagnosis (first step) | Precision diagnosis (second step) | Judge state | | | | | | | |
| Normal () | | 0.8558 | 0.0724 | 0.0718 | | | | | |
| Cavitation () | Mild | 0.3529 | 0.6038 | 0.0433 | 0.7382 | 0.0579 | 0.1763 | 0.0276 | | Medium | 0.2311 | 0.7621 | 0.0068 | 0.9218 | 0.0053 | 0.0204 | 0.0525 | | Severe | 0.3200 | 0.6134 | 0.0666 | 0.9649 | 0.0001 | 0.0098 | 0.0252 | |
| Impeller unbalance () | Mild | 0.2026 | 0.6813 | 0.1161 | 0.0153 | 0.7468 | 0.1934 | 0.0445 | | Medium | 0.1897 | 0.7385 | 0.0718 | 0.0118 | 0.8216 | 0.1430 | 0.0236 | | Severe | 0.1365 | 0.7027 | 0.1608 | 0.0092 | 0.7604 | 0.2259 | 0.0045 | |
| Shaft misalignment () | Mild | 0.3415 | 0.6435 | 0.0150 | 0.1138 | 0.2126 | 0.6072 | 0.0664 | | Medium | 0.2071 | 0.7446 | 0.0483 | 0.0158 | 0.1901 | 0.6831 | 0.1110 | | Severe | 0.3007 | 0.6756 | 0.0237 | 0.0576 | 0.1573 | 0.6315 | 0.1536 | |
|
|