Research Article
Fundamental Frequencies of Vibration of Footbridges in Portugal: From In Situ Measurements to Numerical Modelling
Table 8
Peak acceleration amplitudes for different tests.
| Walking load |
(mg) | Vertical | Longitudinal | Transversal |
| 1 Person*—walk at Hz | 7.3 | 1.7 | 2.9 | 1 Person*—walk at Hz | 10.1 | 1.8 | 3.1 | 1 Person*—walk at Hz | 8.3 | 4.9 | 8.0 | 1 Person*—walk at Hz | 11.6 | 12.2 | 13.5 | 1 Person*—walk at Hz | 15.5 | 7.8 | 15.8 | 1 Person*—walk at Hz | 32.7 | 11.8 | 25.4† | 2 Jumps at mid-span | 61.1 | 34.2† | 90.2† | Impulse in transversal direction | 8.5 | 5.2 | 15.6 |
|
|
74 kg. †Values exceeding the code limits for horizontal vibration (20 mg). EN-1990 [20]).
|