Research Article
The Influence of Pier Stiffness Ratio on the Failure Modes of Masonry Structures
Table 4
The stiffness ratio of pier between windows and spandrel.
| The models | The total stiffness of pier between windows | The total stiffness of spandrel | The stiffness ratio | The total pier between windows and the total spandrel | One piece pier between windows and one piece spandrel |
| Model 1 | 15.25 | 9.66 | 1.58 | 1.76 | Model 2 | 13.63 | 1.41 | 1.51 | Model 3 | 18.83 | 13.20 | 1.43 | 1.58 | Model 4 | 16.59 | 1.26 | 1.32 | Model 5 | 12.72 | 6.00 | 2.12 | 2.35 | Model 6 | 11.60 | 1.93 | 2.10 |
|
|