Research Article
An Energy-Based Safety Evaluation Index of Blast Vibration
Table 1
The main parameters of the surrounding buildings of the blasting area.
| | Building number | Types of buildings | Building height (m) | Status before blast |
| | A | Brick-concrete | 7.3 | Intact | | B | Brick-concrete | 7.5 | Intact | | C | Brick-concrete | 7.1 | Intact | | D | Brick-concrete | 7.3 | Intact | | E | Brick-concrete | 7.0 | Intact | | F | Brick-concrete | 7.1 | Intact | | G | Brick-concrete | 7.4 | Intact | | H | Brick-concrete | 7.8 | Intact | | I | Brick-concrete | 7.6 | Intact | | J | Brick-concrete | 7.6 | Intact | | K | Brick-concrete | 12.5 | Intact | | L | Brick-concrete | 7.2 | Intact | | M | Brick-concrete | 7.3 | Intact | | N | Brick-concrete | 7.5 | Intact | | O | Brick-concrete | 7.5 | Intact | | P | Brick-concrete | 7.4 | Intact | | Q | Brick-concrete | 7.7 | Tiny crack on wall | | R | Brick-concrete | 11.4 | Intact | | S | Brick-concrete | 7.2 | Tiny crack on wall | | T | Brick-concrete | 7.0 | Intact |
|
|