Natural frequencies (Hz) of the aluminum, carbon/epoxy [
8], and glass/epoxy plates obtained by modal test.
| Frequencies | | | | | | | | | | |
| Aluminum | | | | | | | | | | | A1 | 114 | 167 | 218 | 289 | 300 | 497 | | | | | A2 | 39 | 91 | 237 | 261 | 337 | 545 | | | | | Carbon/epoxy | | | | | | | | | | | B1 | 60 | 82 | 143 | 218 | 232 | 257 | | | | | B2 | 111 | 202 | 290 | 310 | 370 | 555 | | | | | C1 | 102 | 311 | 342 | 364 | 390 | 612 | | | | | C2 | 183 | 370 | 535 | 870 | 944 | 1050 | | | | | D1 | 1670 | 3480 | 3860 | 4400 | 5100 | 6300 | 8800 | 9900 | 10500 | 11000 | D2 | 1240 | 2170 | 3310 | 5350 | 6880 | 7030 | 7530 | 8910 | 11340 | 11710 | Glass/epoxy | | | | | | | | | | | C3 | 188 | 385 | 555 | 594 | 669 | 1076 | | | | | C4 | 261 | 279 | 573 | 635 | 682 | 1002 | | | | | D3 | 154 | 471 | 968 | 1626 | 2025 | 2743 | 3439 | 4658 | 5394 | 5819 | D4 | 136 | 654 | 833 | 1792 | 2112 | 2410 | 3968 | 4025 | 5175 | 5824 |
|
|