Research Article
Vibration of Shaft System in the Mixed-Flow Pump Induced by the Rotor-Stator Interaction under Partial Load Conditions
Table 2
Results of energy performance.
| Parameters | 1.0Qdes | 0.4Qdes | 0.2Qdes |
| Inlet pressure(kPa) | 17.99 | 23.72 | 30.44 | Outlet pressure (kPa) | 71.96 | 104.27 | 123.32 | Rotating speed(r/min) | 1450.88 | 1447.7 | 1448 | Torque (N·m) | 58.78 | 60.39 | 70.25 | Shaft power (kW) | 8.93 | 9.15 | 10.65 |
|
|