Research Article

Vibration of Shaft System in the Mixed-Flow Pump Induced by the Rotor-Stator Interaction under Partial Load Conditions

Table 2

Results of energy performance.

Parameters1.0Qdes0.4Qdes0.2Qdes

Inlet pressure(kPa)17.9923.7230.44
Outlet pressure (kPa)71.96104.27123.32
Rotating speed(r/min)1450.881447.71448
Torque (N·m)58.7860.3970.25
Shaft power (kW)8.939.1510.65