Research Article
Research on the Fatigue Properties of High Strength Concrete after Exposure to High Temperature under Low Cyclic Compressive Loading
| Specimen number | | | | |
| P-2-0.5 | 0.835 | 2.19 | 4.46 | 5.20 | P-2-1 | 0.961 | 2.97 | 4.87 | 5.27 | P-2-2 | 0.735 | 1.88 | 4.27 | 5.03 | P-2-3 | 0.686 | 1.76 | 4.11 | 4.96 | P-4-0.5 | 0.770 | 2.01 | 4.30 | 5.11 | P-4-1 | 0.735 | 1.88 | 4.27 | 5.04 | P-4-2 | 0.746 | 1.92 | 4.30 | 5.09 | P-4-3 | 0.739 | 1.89 | 4.28 | 5.06 | P-6-0.5 | 0.415 | 1.53 | 3.77 | 4.62 | P-6-1 | 0.399 | 1.51 | 3.74 | 4.45 | P-6-2 | 0.418 | 1.53 | 3.78 | 4.64 | P-6-3 | 0.402 | 1.51 | 3.70 | 4.60 | P-8-0.5 | 0.394 | 1.50 | 3.66 | 4.39 | P-8-1 | 0.389 | 1.49 | 3.62 | 4.28 | P-8-2 | 0.393 | 1.50 | 3.66 | 4.34 | P-8-3 | 0.395 | 1.50 | 3.67 | 4.33 |
|
|
Note. P-X-X indicates fatigue test-heating temperature- holding time, and P-0 indicates HSC at room temperature.
|