Research Article
Modeling and Stochastic Model Updating of Bolt-Jointed Structure
Table 8
Updated parameters of overall substructure.
| Parameter | Mean (MPa) | SD (MPa) |
| Normal stiffness, | 80.09 | 8.562 | Tangential stiffness, | 39.81 | 4.031 | Tangential stiffness, | 39.97 | 3.879 | Damping coefficient, (%) | 0.107 | 0.016 | Normal stiffness, | 80.11 | 8.437 | Tangential stiffness, | 39.94 | 3.598 | Tangential stiffness, | 40.12 | 3.945 | Damping coefficient, (%) | 0.120 | 0.012 | Normal stiffness, | 50.01 | 4.683 | Tangential stiffness, | 25.01 | 2.619 | Tangential stiffness, | 25.07 | 2.437 | Damping coefficient, (%) | 0.115 | 0.011 |
|
|