Research Article
Investigation of Objective Parameters of Vehicle Door Closing Transient Sound Quality Based on Complex Analytic Wavelet Method
Table 3
The psychoacoustic objective parameters.
| Sample | Loudness (sone) | Sharpness (acum) | Roughness (asper) | Fluctuation strength (vacil) | A-weighted sound level (dB) |
| S1 | 35.2 | 1.41 | 0.0212 | 0.232 | 78.63 | S2 | 38.9 | 1.45 | 0.0234 | 1.55 | 78.78 | S3 | 32.3 | 1.58 | 0.0191 | 0.157 | 74.31 | S4 | 36.1 | 1.62 | 0.0188 | 0.182 | 79.47 | S5 | 25.6 | 1.31 | 0.0225 | 0.118 | 80.70 | S6 | 32 | 1.29 | 0.0229 | 0.226 | 80.02 | S7 | 41.7 | 1.37 | 0.0231 | 0.202 | 77.54 | S8 | 48.3 | 1.4 | 0.0245 | 0.24 | 79.75 | S9 | 35.1 | 1.4 | 0.0277 | 0.222 | 77.36 | S10 | 49.2 | 1.46 | 0.0181 | 0.114 | 79.98 | S11 | 42.2 | 1.55 | 0.0186 | 0.189 | 75.38 | S12 | 34.9 | 1.33 | 0.0231 | 0.145 | 81.68 | S13 | 49.9 | 1.42 | 0.0197 | 0.287 | 76.86 | S14 | 40.6 | 1.43 | 0.023 | 0.219 | 74.69 | S15 | 45 | 1.34 | 0.0227 | 0.223 | 81.36 | S16 | 40.7 | 1.53 | 0.0221 | 0.267 | 77.07 | S17 | 27.9 | 1.54 | 0.0224 | 0.15 | 75.04 |
|
|