Research Article

Dynamic Response of a Combined Isolation Based Mega-Substructure under Bidirectional Near-Fault Ground Motions

Table 5

Displacement response and damping rate of the subframe top floor (mm).

Test casesEarthquakeDirectionInput amplitude3rd subframe2nd subframe
AseismicCombined isolationDamping rateIsolation layerAseismicCombined isolationDamping rateIsolation layer

S1Chi-Chi-2NY0.056 g0.840.364.29%1.041.210.4562.81%0.87

S2Chi-Chi-2FY0.056 g0.720.2368.06%0.861.040.461.54%0.79

B1Chi-Chi-2NX0.051 g0.780.2765.38%1.091.140.4362.28%0.85
Y0.056 g0.910.3264.84%1.171.290.5259.69%0.98

B2Chi-Chi-2FX0.051 g0.670.2168.66%0.831.010.3565.35%0.73
Y0.056 g0.780.2765.38%1.011.080.4162.04%0.85

S3Chi-Chi-2NY0.153 g2.120.6867.92%3.192.610.9264.75%2.73
S4Chi-Chi-2FY0.153 g1.830.6465.03%2.712.380.7867.23%2.34

S5Chi-Chi-3NY0.153 g2.550.8865.49%4.263.041.0864.47%3.81

B3Chi-Chi-2NX0.140 g1.980.6467.68%2.982.540.9164.17%2.56
Y0.153 g2.330.8264.81%3.262.850.9865.61%2.82

B4Chi-Chi-2FX0.139 g1.760.5469.32%2.562.320.7368.53%2.27
Y0.153 g2.010.6766.67%2.932.530.7869.17%2.51

B5Chi-Chi-3NX0.113 g2.310.7667.10%4.042.911.0264.95%3.64
Y0.153 g2.680.9166.04%4.483.281.1265.85%3.94

S6Chi-Chi-2NY0.316 g3.541.3661.58%6.784.111.5263.02%5.26

S7Chi-Chi-2FY0.316 g3.091.0466.34%5.413.541.2165.82%4.47

S8Chi-Chi-3NY0.316 g4.111.5463.26%8.244.561.6464.04%5.83

B6Chi-Chi-2NX0.289 g3.531.1667.14%6.573.821.4661.78%4.86
Y0.316 g3.931.4163.61%6.984.661.6863.95%5.24

B7Chi-Chi-2FX0.288 g3.141.0367.20%5.073.641.2465.93%3.86
Y0.316 g3.421.1566.37%5.424.131.2769.25%4.27

B8Chi-Chi-3NX0.297 g3.931.5161.58%7.864.631.7661.99%5.56
Y0.316 g4.421.6163.57%8.425.121.9162.70%5.88